Hydraulic bending machine safety operation procedures

The operator must strictly follow the safe operation procedures of the bending machine. If an abnormality is found during the operation, the operator should immediately stop the operation and check the cause of the stoppage. The safety operation rules of the bending machine are as follows:
1. Strictly abide by the safety rules of the machine tool workers and wear labor protection articles as required.
2, before the boot should be the upper and lower mold clean, wipe clean.
3. Check if there are any foreign objects on the racks, stopper racks and sliders. If there are foreign objects, they should be cleaned.
4, according to the thickness of the folded sheet, select the appropriate die, die size is generally equal to or greater than 8 times the sheet thickness.
5. The bending force of the workpiece is obtained from the calculation formula of the bending force of the sheet or the bending force, and the bending force of the workpiece must not be greater than 1000 KN.
6. When bending narrow sheets, the working pressure of the system should be properly reduced to avoid damage to the mold.
7, adjust the slider stroke, should ensure that the adjustment is less than 100, so as not to damage the machine.
8. Before bending, the gap between the upper and lower molds should be adjusted uniformly.
9. When bending, do not put your hand between the molds. Only one piece of material can be folded at a time, and not many pieces are bent at the same time. Check the oil level of the tank and start the oil pump to check for any abnormalities in the hydraulic piping and the oil pump.
10. The bent sheet should be placed in the middle of the mold. The machine should not be unilaterally loaded so as not to affect the accuracy of the workpiece and the machine. If some workpieces need to work unilaterally, the load should not be greater than 250KN, and the two sides must be bent at the same time.
11. Check the oil level of the tank and start the oil pump to check whether there is any abnormality in the hydraulic pipe and the oil pump.
12. Abnormally stop immediately, check the cause and eliminate it in time.
13. After the operation is completed, the oil pump should be turned off, exit the control system program, and cut off the power supply.

Low voltage pvc insulated electric wire has been widely used in our country with the advantages of excellent electric properties, strong ability to resist short circuit, long service life , easy to install, operate and maintain, etc      

     The product of low voltage stranded pure copper 2.5mm 6mm electric cable  belong to the series of laying electric wires,  which is mainly suitable for laying at the fixed places,  It is widely used as connectors of drive, lighting , electronic equipments  , Instrument and telecommunication equipments with rated voltage 450/750v or below ,  Part of plastic wires are used at the equipment with A.C rated votage 300/300v or below.

Standards:     ASTM / ICEA S-76-474 , IEC 60502 ,DIN,  NFC 33-209 , BS 7870 GB/T 12527 etc

Nominal section.(mm2) conductor No./Dia (mm) Insulated thick (mm) Max.overall Dia. (mm) Conductor resistance at 20'C Weight (kg/km)
copper aluminum copper aluminum
1.5 1/1.38 0.7 3.3 12.1   19.2  
2.5 1/1.78 0.8 3.9 7.41 11.8 30.8 15.0
4 1/2.25 0.8 4.4 4.61 7.39 45.5 21.0
6 1/2.76 0.8 4.9 3.08 4.91 65.0 29.0
10 7/1.35 1.0 7.0 1.83 3.08 110.0 52.0
16 7/1.70 1.0 8.0 1.15 1.91 170.0 70.0
25 7/2.14 1.2 10.0 0.727 1.20 270.0 110.0
35 7/2.52 1.2 11.5 0.524 0.868 364.0 150.0
50 19/1.78 1.4 13.0 0.387 0.641 500.0 200.0
70 19/2.14 1.4 15.0 0.268 0.443 688.0 269.0
95 19/2.52 1.6 17.5 0.193 0.320 953.0 360.0
120 37/2.03 1.6 19.0 0.153 0.253 1168.0 449.0
150 37/2.25 1.8 21.0 0.124 0.206 1466.0 551.0
185 37/2.52 2.0 32.5 0.099 0.164 1808.0 668.0

Pure Copper Wire

Pure Copper Wire,4Mm Pure Copper Wire,Flexible Cable Wire,Pvc Pure Copper Wire