Domestic hot water circulation pump head how to determine

For the domestic hot water circulation pump, its head is the highest distance the water pump can send water up to, the origin of the circulating pump water And at the same end of the same height, and did not go to send high, all that no problem with the smaller head. How to determine the home hot water circulation pump head How to determine the home hot water circulation pump head: 1, circulating pump flow rate by the general design of the hour to determine the percentage of hot water. Designed for single-hour hot water 25 - 30% of the district for the design of hot water 30 - 35%. 2, the head of the circulating pump calculated by the above-mentioned flow through the water supply and backwater pipeline losses, if it is through the instant or semi-instantaneous heater, but also calculated or in accordance with the parameters given by the manufacturer set losses. The two add up, and then multiply the multiples of 1.1 as the pump head. 3, circulating pump control through the return pipe before the pump temperature sensor to control start and stop. Start-stop temperature is generally 10 ° higher than the hot water supply pump, low 5 ° stop pump. Pump head: H = SQ ^ 2 Where: S - the total friction resistance of the circulating line; pump head lift - circulation flow. For selected pumps and pipelines, the flow Q = (H / S) ^ (1/2) if the total head loss of the pipe is equal to the head of the pump. If the total head loss of the pipe is not equal to the head of the pump, It should be determined by the characteristic equation of the pump and the characteristic equation of the pipe: H = SQ-2 = H0 = Ho / SoQ ^ Where: So - internal friction resistance of the pump; Ho - pump head when the flow is zero, can be found by the pump characteristic curve. H - pump head or pipeline head loss. There is no difference between head and flow when water point and pump height are +10 meters and -10 meters, but it must be noted that there should not be too large negative head (negative pressure) in the pipeline to avoid cavitation of pipeline or pump, or even not normal work. Domestic hot water circulation pump in addition to considering water distribution, backwater and other pipe network head loss, the head is the water pump to the water up to the maximum distance. The origin and end of the circulating pump water at the same level, and did not go to send high, so to say a small lift no problem.

We can produce the A/SA106B/C steel pipes according to the ASME SA106 and ASTM A106 standards, YC has been granted a number of approval certificate by international institutions, such as Nuclear pipe certificate, 914mm Cylinder certificate, API monogram and certificate, ISO9001 by TUV NORD, ISO14001/OHSAS18001 by CQC, approvals from Shipping Classification Bureaus like DNV, RINA, ABS, Lloyd, GL, Bureau Veritas, and permit of exporting to Europe as PED 2014/68/EU and AD 2000 certificates for pressure pipes, CPD (Construction Products Directive), etc.


Chengde have been working on the research.manufacture and sale of seamless pipe about 30 years, and the advantage of core competence is more prominent by integrate in technical.management and market with PCC.

1 The Piercing and rolling technology of Chengde possesses a number of patents in designing and manufacturing the equipment. The production is efficient and flexible, and the quality is stable.

2 The material grade is complete, and the size range is wide (three produce line can manufacture all non-standard sizes).  The Minimum Order Quantity (MOQ) as low as ONE piece, and the date of delivery is short with excellent cost performance.

3 The sales and service team is professional and localize.


ASME SA106 Steel Pipe

ASTM A106 Carbon Steel Pipe

Mechanical Pipe,Astm A106 Pipe,106B Pipe,Astm A106 Carbon Steel Tube

YANGZHOU CHENGDE STEEL PIPE CO.,LTD , https://www.chengdepipe.com