Acceptance standards for engineering, ceiling, and plastic sheet surface engineering

>>> This site friend integrated ceiling installation experience

Acceptance criteria for the flower decoration project: After the flower decoration project is completed and dried, it can be accepted. Acceptance of the floral decoration project shall check whether the variety, size and pattern of the floral ornament meet the design requirements. The floral ornament shall be firmly installed. Its quality requirements and allowable deviations shall conform to the provisions: the horizontal and vertical allowable deviation of the striped floral ornament shall not exceed 5mm per meter. Must not be greater than 3mm; the allowable deviation of the position of the individual floral ornament is greater than 10mm; the surface of the floral ornament should be smooth and clean, the pattern should be clear, and the joints must be tightly closed with no defects such as cracks, warpage, missing edges, etc.; the surface of the flower should be clean and clear, and the pattern should be clear. crack.

Ceiling acceptance criteria: The variety, specification, color of the materials used in the ceiling project, and the basic structure and fixing method should meet the requirements of the design specification; the cover panel and the keel should be tightly connected, the surface should be flat, and there should be no pollution, cracks, missing edges. Defects such as hammers and hammers shall be uniform and consistent. There shall be no delamination phenomenon of the glued cover panel, and the plywood shall not be penetrated; the shelving panel shall not have any leakage, penetration, or warping angle.

Acceptance standards for construction quality of plastic sheet surface: The material, color, and paving should meet the requirements of living: The surface should be smooth, wrinkle-free, and must not be curled or bubbling; the color and color should be the same, the seam must be straight and straight, and the degumming should not be more than 20cm. The spacing between them shall not be less than 500mm; the joint with the pipeline shall be tight, firm and flat; the skirting board shall be closely connected with the plastic; the full length height difference shall not be greater than plus or minus 3mm, and shall be close to the wall with no gap.

Construction acceptance

Flexible Air Duct Hose

Air Conditioning Hose,Air Duct Tube,Spiral Ducting

Fenghua Jade Motor Co., Ltd. , http://www.composite-hose-supplier.com